← All plans

The Juniper

2,001 sq ft

4-bed · 4-bath · Open plan · 69 × 29 ft footprint · 15 rooms

Show:
floor plan, 69 by 29 feetREFDWMWWDPorchEGREGREGREGRLiving289 sq ftDining103 sq ftPowder Room45 sq ftKitchen161 sq ftBedroom 4126 sq ftBath 172 sq ftBath 274 sq ftLaundry72 sq ftHall254 sq ftPrimary Bed202 sq ftPrimary BathBedroom 2141 sq ftBath 374 sq ftBedroom 3153 sq ftOffice131 sq ftFRONT / STREET010 ftN

Tip: click a room, or hover an item (sink, fridge…) and click for details

Design-quality audit

An objective, weight-independent measure of craft — how faithfully the plan follows code + cited best practice. (Separate from your personal priorities, which you set in the studio.)

93
/ 100
✓ Code-compliant (all mandates)Usable area 87.3%Circulation 12.7%Avg room proportion 1.67:1
Every room is reachable from the entry · Walking-path best practice
No fixture or furniture blocks a doorway/entrance · Clear-floor best practice (NKBA / IRC R307.1)
No bedroom reached only through another bedroom · IRC R311 / functional-obsolescence best practice
Every habitable room has a window (daylight + egress) · IRC R303.1 / R310
Every bedroom has an emergency-escape window · IRC R310 (emergency escape & rescue opening)
Bed headboard not under a window · Best practice (interior design)
Sink + toilet share a plumbing wall (not opposite walls) · Best practice (plumbing economy / circulation)
No sliver rooms (sane proportions) · Proportion guides (≈1.15–1.6:1 ideal)
Circulation ≤ 14% of floor (no dead-end hall) · Young Architect — net/gross efficiency
Primary is the largest bedroom · NAHB convention
Bedrooms are a sane rectangle (not a corridor) · Proportion guides (≈1.5–1.6 : 1 ideal)
Laundry/utility room is functional-sized (not oversized) · Service-room sizing (sized to fixtures, not floor)
Half-bath is the smallest bath; primary bath isn't the runt · Bath-program convention (NAHB / NKBA)
Powder room sized to a half-bath (not oversized) · Half-bath sizing (toilet + sink, ~20-30 sq ft)
Every bedroom near a usable full bath · NKBA bedroom-to-bath
Front door enters a social/transition space · Front-door best practice
Coat closet within a step of the front door · Best practice (NAHB entry storage)
Clear floor in front of coat/linen closet doors · Clear-floor best practice (reach-in access)
Every living/family room has a sofa (not only a TV) · Best practice (a living room's primary furniture)
Sofa within comfortable viewing distance of the TV (gap ≈ ≤ 2× screen diagonal) · Viewing-distance best practice (SMPTE/THX)
Range/cooktop not under a window · NKBA Guideline 18
Wide opening (≥ 6 ft) from the kitchen to the living/dining · NAHB most-wanted (open kitchen/living)
Kitchen work triangle not sprawling (sink+range+fridge legs ≤ 26 ft total) · NKBA Guideline 3
Kitchen work flow: sink between the fridge and range · NKBA (wash → prep → cook)
Dishwasher within 36 in of the sink · NKBA Guideline 24
Bedroom door near a corner (long wall stays unbroken for the bed) · Best practice (bedroom layout)
A usable walkway (≥ 2 ft) in front of the bed · NKBA bedroom clearance
Room to pull out chairs + pass around the dining table · Best practice (dining clearance)
Stand-and-load room in front of the washer/dryer · Best practice (appliance access)
Washer + dryer side by side (short reach to transfer) · Best practice (laundry workflow)
Clear floor in front of the refrigerator (doors + standing) · NKBA (fridge landing + access)
Tub/shower set back behind the sink — not blocking the walk in · NKBA fixture sequence
Sink nearest the door, with room to stand at it · NKBA fixture sequence + clear floor (IRC R307.1)
Bath vanity keeps mirror wall — window beside it, not behind · NKBA
Tub/shower set flush in a corner (alcove, plumbing on one corner) · Alcove-fixture best practice
At least one tub in the home (resale) · Resale/bathing best practice
Primary bedroom has a closet/walk-in · Convention
Closets tuck against a wall (not protruding into the room) · Best practice (built-in storage)
Clear floor in front of a dresser (drawer pull) (Bedroom 2) · NKBA / interior-design clearance
Kitchen counter frontage (NKBA, scaled to kitchen size) (5.6 / 12.1 ft) · NKBA Guideline 25
Counter (landing) on both sides of the kitchen sink (missing on a side) · NKBA Guideline 11

Fixture-placement check

An automatic sweep for physical placement problems — fixtures overlapping, a blocked door, a toilet with no standing room, a TV off the sofa, a bedroom that reads as a corridor once the closet is removed.

✓ No placement conflicts — everything fits and clears.

A curated, code-compliant starter plan the engine warm-starts from. Want one tuned to your lot and priorities? Open the Design Studio.

Preliminary and advisory — a schematic layout to explore, never a stamped construction document.

v0.1.0 · 459b17b · 2026-07-20