Current page: Indoor airPLUS §Moisture Control — bulk water management
GuidelineRecommended

Bulk water management: site drainage 6 in/10 ft away, capillary break above foundation, drainage plane behind cladding

Indoor airPLUS §Moisture Control — bulk water management

Description

Indoor airPLUS requires bulk-water management at every envelope boundary: site graded ≥ 6 in fall in the first 10 ft (5%) away from the foundation; gutters + downspouts discharging ≥ 5 ft from foundation; capillary break (sill seal, rigid foam, sheet membrane) above the foundation wall; drainage plane behind ALL exterior cladding (rain-screen detail required for stone / brick / large-format claddings); flashing at all wall penetrations.

Why this exists

Water in walls + foundations is the #1 trigger of mold + IAQ problems. The airPLUS bulk-water rules are the architect's design checklist for keeping water OUT of the assembly. Combined with the ENERGY STAR water-management items, this is the most comprehensive residential moisture-protection spec available for free.

Categories

StructureSiteVentilation

Source

US EPAno manifest entry
Indoor airPLUS Construction Specifications (Version 2 / Version 1 Rev 4)
Section: Moisture Control — bulk water management
Published 2024-01-01 · last verified 2026-05-15