Current page: 2025 RCNYS §M1502.3 Dryer exhaust termination 3 ft from openings
CodeMandatory

Dryer exhaust must terminate outside, ≥ 3 ft from any building opening, with backdraft damper, no screen

2025 RCNYS §M1502.3 Dryer exhaust termination 3 ft from openings

Description

Dryer exhaust ducts must terminate on the outside of the building (not into an attic, crawl space, or soffit). Where the dryer manufacturer's instructions don't specify, the termination must be at least 3 ft in any direction from openings into the building — including openings in vented soffits. The termination requires a backdraft damper. Screens are NOT allowed at the termination (they clog with lint). Termination opening must provide ≥ 12.5 sqin of free area.

Why this exists

Lint discharged into attics is the common defect that causes dryer-fed fires and moisture damage. The 3-ft separation prevents the warm wet exhaust from being immediately drawn back into a soffit vent. Architects should show the dryer termination location + clearances on the elevations.

Measurements

PropertyOperatorValueUnitNote
openingSeparationmin3ftSeparation from any building opening
freeAreamin12.5sqinMinimum termination free area

Categories

Life safetyVentilation

Applies to

  • Jurisdiction: New York State

Source

NY Dept of State / ICCno manifest entry
2025 Residential Code of New York State (2025)
Section: M1502.3 Dryer exhaust termination 3 ft from openings
Published 2025-07-01 · last verified 2026-05-15

Solver enforcement

Browsable only — the solver does not currently enforce this directive (no spec-level data to check against). This entry exists so the architect personas can cite it in conversation and the user can read what the rule says.