2025 RCNYS §M1505 Mechanical ventilation (whole-house + local)

Description

Where local exhaust or whole-house mechanical ventilation is provided (or required to satisfy R325 alternatives), the system must comply with M1505. Exhaust air from bathrooms / toilet rooms / kitchens shall NOT be recirculated; it must discharge directly to the outdoors. Whole-house ventilation systems must be designed per M1505.4 (typical: 0.35 ACH or 7.5 cfm/person + 1 cfm/100 sqft). Local exhausts must meet Table M1505.5 — bathroom 50 cfm intermittent OR 20 cfm continuous, kitchen 100 cfm intermittent (vented hood) OR per appliance rating.

Why this exists

Modern tight envelopes (R402.5.1) make passive ventilation insufficient. Architects designing to ECCC NY must include a whole-house ventilation strategy — typically a balanced ERV in cold climates. The bath/kitchen exhausts are then sized + ducted as a coordinated system, not afterthought fans.

Measurements

PropertyOperatorValueUnitNote
bathIntermittentmin50cfmBathroom intermittent exhaust rate
bathContinuousmin20cfmBathroom continuous exhaust rate
kitchenIntermittentmin100cfmKitchen intermittent exhaust rate (vented hood)

Categories

VentilationEnergy

Applies to

  • Jurisdiction: New York State

Source

NY Dept of State / ICCno manifest entry
2025 Residential Code of New York State (2025)
Section: M1505 Mechanical ventilation (whole-house + local)
Published 2025-07-01 · last verified 2026-05-15