Current page: 2025 RCNYS §R309.2 One- and two-family sprinklers
CodeMandatory

One- and two-family dwellings 3+ stories above grade require automatic sprinklers

2025 RCNYS §R309.2 One- and two-family sprinklers

Description

Single-family + duplex dwellings with three or more stories above grade plane must be sprinklered per P2904 or NFPA 13D. Manufactured homes and additions to existing un-sprinklered buildings are exempt.

Why this exists

Most modern walk-out basement / 2-story / habitable-attic homes can hit three above-grade stories depending on how the basement is classified. The architect must determine story count early — if you're going to be at three stories, the sprinkler system is non-negotiable.

Categories

Life safetyStructure

Applies to

  • Jurisdiction: New York State

Source

NY Dept of State / ICCno manifest entry
2025 Residential Code of New York State (2025)
Section: R309.2 One- and two-family sprinklers
Published 2025-07-01 · last verified 2026-05-15