Current page: 2025 RCNYS §R325.1.2 Natural ventilation
CodeMandatory

Habitable rooms: openable area ≥ 4% of floor area (or mechanical 0.35 ACH whole-house)

2025 RCNYS §R325.1.2 Natural ventilation

Description

Habitable rooms must have an aggregate openable area to the outdoors equal to at least 4% of the floor area — through windows, skylights, doors, or louvers. Openings must be readily accessible / controllable by occupants. Alternative: a whole-house mechanical ventilation system capable of 0.35 air changes per hour per M1505, OR a kitchen local-exhaust system per M1505. Adjoining sunrooms / porches count for ventilation under specific conditions.

Why this exists

4% openable area is roughly half the 8% glazed-area requirement — a typical double-hung window meets both at once. Mechanical alternatives matter in tight envelopes (modern high-R homes can't rely on infiltration). Architects designing to current energy code should plan whole-house mechanical ventilation from day one.

Measurements

PropertyOperatorValueUnitNote
openableSharemin4% of floor areaOpenable area as share of room area
wholeHouseACHmin0.35ACHMechanical whole-house ventilation rate (M1505 alternative)

Categories

VentilationLife safety

Applies to

  • Jurisdiction: New York State

Source

NY Dept of State / ICCno manifest entry
2025 Residential Code of New York State (2025)
Section: R325.1.2 Natural ventilation
Published 2025-07-01 · last verified 2026-05-15