Current page: 2025 RCNYS §R703.2 Water-resistive barrier material
CodeMandatory

WRB: ASTM D226 Type I felt (#15), ASTM E2556 Type 1 or 2 housewrap, or foam plastic insulating sheathing systems

2025 RCNYS §R703.2 Water-resistive barrier material

Description

Water-resistive barriers must be at least: (1) No. 15 asphalt felt (ASTM D226 Type I); (2) ASTM E2556 Type 1 or 2 housewrap; (3) foam plastic insulating sheathing systems complying with R703.1.1; (4) an ASTM E331-tested assembly; or (5) other approved materials. WRB layers must be lapped horizontally — upper layer over lower by ≥ 2 in, with joints lapped ≥ 6 in. Accessory structures (sheds, playhouses) without insulation or interior finish are exempt.

Why this exists

Tyvek-style housewraps (ASTM E2556) are the residential default. They tear and require careful detailing around penetrations; 30# felt is more robust but heavier. The 2-in horizontal / 6-in joint laps are commonly missed by less-experienced installers — call them out on the wall detail.

Measurements

PropertyOperatorValueUnitNote
horizontalLapmin2inUpper-over-lower horizontal lap
jointLapmin6inJoint lap dimension

Categories

Structure

Applies to

  • Jurisdiction: New York State

Source

NY Dept of State / ICCno manifest entry
2025 Residential Code of New York State (2025)
Section: R703.2 Water-resistive barrier material
Published 2025-07-01 · last verified 2026-05-15

Solver enforcement

Browsable only — the solver does not currently enforce this directive (no spec-level data to check against). This entry exists so the architect personas can cite it in conversation and the user can read what the rule says.

Related directives

Last reviewed 2026-05-15.