Description

Continuous insulation (rigid foam or mineral wool) outside the wall sheathing breaks the thermal bridge created by wood studs. Effective R-value of the assembly: nominal cavity R + CI R-value × ~0.9 (small loss at fastener penetrations). Typical strategies: 1-2 in of XPS or polyiso outside the sheathing; rainscreen + cladding outside that. Limit is determined by climate-zone vapor-control requirements + fastener-shear limits for the cladding. Long fasteners reach through the foam into the framing.

Why this exists

A 2×6 wall with R-23 cavity insulation but no CI performs at about R-15 effective because of stud bridging. Add R-10 CI and you reach R-25 effective. CI is one of the highest-leverage envelope improvements for the cost; it's also the easiest way to comply with energy codes that target whole-assembly R-values.