Climate Zone 4 (NY downstate, NJ, MD): ceiling R-49 / wall R-20 OR R-13+R-5ci / floor R-19 / slab edge R-10 (2 ft)

IECC R-value (DOE climate-zone) — CZ 4 Envelope R-values (NY downstate)

Description

IECC 2021/2024 prescriptive envelope R-values for Climate Zone 4 (Long Island, NYC, much of NJ, MD): ceiling R-49 (R-60 in 2024 high-performance path); wall cavity R-20 in 2×6 framing OR R-13 cavity + R-5 continuous insulation (CI); mass walls R-8/13; floor R-19; basement walls R-10/13 (interior); slab-edge R-10 to 2 ft depth in heated slabs; crawlspace walls R-10/13. Window U-factor ≤ 0.30; SHGC ≤ 0.40.

Why this exists

These prescriptive values are the floor for energy compliance. The R-13+R-5ci wall option (with continuous insulation) is the ENERGY STAR / Indoor airPLUS preferred path — eliminates the stud thermal bridge. Architects should call out the assembly strategy (cavity-only vs cavity + CI) at schematic.

Measurements

PropertyOperatorValueUnitNote
ceilingmin49R-valueCeiling R-49 minimum
wallCavitymin20R-value cavityWall R-20 cavity (2×6)
floorCavitymin19R-valueFloor R-19
basementInteriormin10R-valueBasement wall R-10 (interior)
windowUmax0.3U-factorWindow U-factor maximum
windowSHGCmax0.4SHGCWindow SHGC maximum

Categories

EnergyStructure

Source

US DOE / ICCno manifest entry
IECC Climate-Zone Prescriptive Envelope (DOE Building America) (IECC 2021 / 2024 reference)
Section: CZ 4 Envelope R-values (NY downstate)
Published 2024-01-01 · last verified 2026-05-15

Solver enforcement

Browsable only — the solver does not currently enforce this directive (no spec-level data to check against). This entry exists so the architect personas can cite it in conversation and the user can read what the rule says.

Related directives

Last reviewed 2026-05-15.