Skip to main content
Almost an Architect
Current page: 2025 RCNYS §M1503.6 Makeup air for high-rate exhausts (>400 cfm)
CodeMandatory

Kitchen exhaust > 400 cfm requires makeup air with damper (auto-opens with exhaust); gas-burning trigger

2025 RCNYS §M1503.6 Makeup air for high-rate exhausts (>400 cfm)

Description

When a gas, liquid, or solid-fuel-burning appliance that isn't direct-vent or mechanical-draft is located within a dwelling's air barrier, AND any single exhaust system can move more than 400 cfm, makeup air at approximately the exhaust rate must be supplied — through at least one outdoor air duct with a damper that opens automatically when the exhaust runs. Exception: space-cooling exhausts intended only when windows are open.

Why this exists

Pro-grade range hoods (1000+ cfm) without makeup air create dangerous negative pressure that backdrafts gas water-heater fumes (CO!) into the dwelling. Architects specifying high-cfm hoods MUST also spec a makeup-air system; this is a non-negotiable life-safety detail.

Measurements

PropertyOperatorValueUnitNote
makeupTriggermin400cfmExhaust rate triggering makeup-air requirement

Categories

Life safetyVentilationKitchen

Applies to

  • Jurisdiction: New York State

Source

NY Dept of State / ICCno manifest entry
2025 Residential Code of New York State (2025)
Section: M1503.6 Makeup air for high-rate exhausts (>400 cfm)
Published 2025-07-01 · last verified 2026-05-15

Solver enforcement

Browsable only — the solver does not currently enforce this directive (no spec-level data to check against). This entry exists so the architect personas can cite it in conversation and the user can read what the rule says.

Related directives

Last reviewed 2026-05-15.