Current page: 2025 RCNYS §R310.3 Smoke alarm location requirements
CodeMandatory

Smoke alarms must be in each sleeping room, outside each sleeping area, on each story, away from baths and cooking

2025 RCNYS §R310.3 Smoke alarm location requirements

Description

Required smoke alarm locations in NY: (1) inside each sleeping room; (2) outside each separate sleeping area, in the immediate vicinity of the bedrooms; (3) on every additional story including basements + habitable attics; (4) at least 3 ft horizontally from any bathroom containing a tub or shower (where this doesn't prevent required placement); (5) in hallways AND in rooms open to the hallway when the open-room ceiling exceeds the hallway by 24 in or more; (6) within sleeping-loft rooms; (7) in shared common spaces of buildings with 3+ dwelling units. On any level over 1000 sqft, the ceiling must have an alarm within 30 ft travel distance from every point (or one alarm per 500 sqft).

Why this exists

The 30-ft / 500-sqft density rule is unique to NY and changes coverage for vaulted-ceiling great rooms. The 3-ft horizontal stand-off from bathrooms minimizes false alarms from shower steam. Architects should locate alarms on the plan during schematic; placing them after rough-in is expensive.

Measurements

PropertyOperatorValueUnitNote
bathStandoffmin3ftStand-off from bath with tub/shower
densityAreamax500sqft per alarmFloor area per smoke alarm on levels >1000 sqft
densityTravelmax30ftTravel distance from any ceiling point to a smoke alarm on levels >1000 sqft

Categories

Life safetyElectrical

Applies to

  • Jurisdiction: New York State

Source

NY Dept of State / ICCno manifest entry
2025 Residential Code of New York State (2025)
Section: R310.3 Smoke alarm location requirements
Published 2025-07-01 · last verified 2026-05-15