COEntry64 sqftglazing 9.4%EGRESSLiving240 sqftglazing 14.2%Kitchen150 sqftglazing 8.0%SHall64 sqftEGRESSSBedroom170 sqftglazing 12.9%EGRESSSBedroom150 sqftglazing 9.3%Bath70 sqftglazing 5.7%Bath60 sqftglazing 6.7%36.8 ft26.3 ft

Tip: click a room, window, or door to see what governs it.

About this plan

A single-level cape cod with two bedrooms, two full baths, and wider 34-inch interior doors and 44-inch halls throughout. The primary suite and an open core make this an easy long-term home.

single levelaccessibleaging in placewide doors

Juniper

cape cod

A barrier-friendly 2-bedroom built for aging in place.

Bedrooms
2
Bathrooms
2
Size
968 sqft
Stories
1
Make this plan mine →

Opens in the studio — refine it with the weight sliders.

Building-code check

All pass
  • Emergency escape opening — minimum clear dimensions (IRC 2021 R310.2.1)
  • Natural light — minimum glazing ratio (IRC 2021 R303.1)
  • Habitable room — minimum ceiling height (IRC 2021 R305.1)
  • Habitable room — minimum floor area (IRC 2021 R304.1)
  • Habitable room — minimum horizontal dimension (IRC 2021 R304.2)
  • Natural ventilation — minimum openable ratio (IRC 2021 R303.1)
  • Hallway — minimum clear width (IRC 2021 R311.6)
  • Required egress door — minimum clear width (IRC 2021 R311.2)
  • Smoke alarm — required in each sleeping room (IRC 2021 R314)
  • Carbon monoxide alarm — required near sleeping areas (IRC 2021 R315)

We check the IRC fundamentals shown here. We do not check state/local amendments, structural engineering, or mechanical systems — your local professional handles those.

Livability check

No problems
  • !Living room renders 2.5:1 in this layout — narrower than the ~1.7:1 ideal. (Habitable rooms not corridor-like)
  • !A door into Entry has only 1.7 ft to swing — tight for a 3.0 ft door. (Door swings don't collide)
  • !A door into Entry has only 1.7 ft to swing — tight for a 2.8 ft door. (Door swings don't collide)
  • !A door into Hallway has only 2.4 ft to swing — tight for a 2.8 ft door. (Door swings don't collide)
  • !A door into Hallway has only 2.4 ft to swing — tight for a 2.8 ft door. (Door swings don't collide)
  • !A door into Hallway has only 2.4 ft to swing — tight for a 2.8 ft door. (Door swings don't collide)
  • !A door into Hallway has only 2.4 ft to swing — tight for a 2.7 ft door. (Door swings don't collide)

These are architect rules of thumb the building code doesn't cover — room reachability, proportion, daylight, and adjacency. Warnings are nudges, not failures. Sourced from A Pattern Language, NKBA, and practitioner conventions.

Estimated cost

$176,350

≈ $182/sqft, shell + finishes

A transparent takeoff from the plan's actual rooms and openings — not a regional per-sqft guess. Real bids vary with site, market, and finish level.